Turbine Flow Sensor Electrical Characteristics

- Oct 16, 2017 -

1, display:

(1) LWGY remote display: pulse output (with display instrument);

(2) LWY field display: liquid crystal display cumulative flow, the unit (m & sup3;)

Liquid crystal display instantaneous flow, unit (m & sup3; / h)

(3) LWGB turbine flow transmitter: (with display instrument).

2, the output function:

(1) LWGY pulse output, p-p value determined by the power supply;

(2) LWY with pulse output or 4 ~ 20mA two-wire current output;

(3) LWGB 4 ~ 20mA two-wire current output.

3, power supply:

(1) LWGY: DC5 ~ 24V;

(2) LWY: 3V lithium battery installed in the instrument can be used continuously for 3 to 5 years; 


technical advantages

Turbine flow sensor with high precision, good repeatability, no zero drift, high range ratio and so on. Turbine flowmeter with high-quality bearings, specially designed deflector, thus greatly reducing the wear, the peak is not sensitive, even under bad conditions can also give reliable measurement variables. Turbine flowmeter output signal for the pulse, easy to digitize. Turbine flowmeter pressure loss is small, the blade can be anti-corrosion, can measure viscous and corrosive media.