Top mounted magnetic flap level gauge

- Jan 26, 2018 -

Top mounted magnetic flap level meter is installed directly on the top of the container, with the float by the liquid (or interface) up and down movement of the magnetic link up and down movement by the magnetic link within the magnetic coupling principle of magnetic coupling Plate indicator, with red and blue colors (liquid red gas blue) clearly indicates the level of the craft container or boundary, the remote transmission and automatic control. UFDZ series top mounted magnetic flap level gauge mainly consists of body part, local indicator, remote transmitter and upper and lower limit alarm and other parts.

Technical Parameters

1. Measuring range: 0-4000mm

2. Nominal pressure: 1.0MPa; 1.6MPa; 2.5MPa; 4.0MPa

3. Nominal diameter: DN150

4 working temperature: -40 ~ 80 ℃

5. Measurement accuracy: ± 10mm

6. Medium density: Level: ρ ≥ 0.5g / cm3

Boundary: ρ1-ρ2 ≥ 0.25g / cm3

7. Wetted material: 1Cr18Ni9Ti

8. Flange standard: JB82-59 (level gauge flange: flat or convex flange

9. Heat Jacket Connector: ZG1 / 2 "(female)

10. Upper and lower limit alarm: Output signal: a normally open, normally closed two (or two normally open, two normally closed orders please specify)

11. Ambient temperature: -20 ~ 40 ℃

12. Operating temperature: -40 ~ 120 ℃

13. Measurement accuracy: ± 10mm

14. Working life: ≥105

Protection class: IP65

16. Power inlet: M20 × 1.5 (female)

17. Explosion-proof form, explosion-proof mark:

Flameproof: dIIBT4

Intrinsically safe: iaIICT5

Installation and Maintenance 

1, level gauge catheter and the main catheter must be kept vertical

2, connecting rod can not be bent, it must be inserted straight

3, after the installation is completed, need to turn on the display magnet with a guide so that more than zero white, zero below the red.