Stainless Steel Electromagnetic Beer Flow Meter RS485 4-20mA Tri Clamp

Stainless Steel Electromagnetic Beer Flow Meter RS485 4-20mA Tri Clamp

Widely used for beer flow measurement; High Accuracy 0.5%; Output:4-20mA output; RS485 Modbus; GPRS wireless data transfer.

Send Inquiry

Product Details

Stainless Steel Electromagnetic Beer Flow Meter RS485 4-20mA Tri Clamp


Electromagnetic Flow Meter

Measuring Principles

The measuring principle of electromagnetic flowmeter is based on the electromagnetic induction law of Farady. The sensor is mainly composed of measuring tube with isolate lining, a pair of electrodes installed by penetration of the measuring tube wall, a pair of coils and iron core to produce working magnetic field. When the conductive fluid flows through the measuring tube of the sensor, the voltage signal in direct proportion to the average flow velocity of the fluid will be inducted on the electrodes. The signal is amplified and treated by the transmitter to realize various display functions

20171023103835.jpg

 

 

Photo

ConverterCompactRemoteCompact with Battery Power
Accuracy0.5% of Rate0.5% of Rate1.0% of Rate
Conductivity>5μs/cm>5μs/cm>5μs/cm
Min. Velocity0.3 m/s0.3 m/s0.3 m/s
Max. Velocity10 m/s10 m/s10 m/s
Turndown RationStandard 1:20; Others on request
Output4-20mA/Pulse4-20mA/PulseConsult the factory
Power Supply(1) 110-240Vac(1) 110-240VacLithium Battery
(2)  18-36 Vdc(2)  18-36 Vdc
CommunicationOptional: RS485; MODBUS; HART; Profibus-DP
Ex-Proof LevelExd[ia]qIICT5
Protection LevelIP65Converter: IP65IP65
Sensor: IP65; (IP68 on request)
DiameterDN10-DN1200
Installation1. Flange (Standard: ISO; Optional: ANSI, DIN, JIS);
2. Thread (Standard: G; Optional: NPT);
3. Wafer
Pressure RatingStandard: 1.6Mpa; Others on request
Fluid TemperatureStandard: PTFE: <120°C (customized PTF)E: <120°C) ;  
Rubber: <60°C
Ambient Temperature-30°C-60°C-30°C-60°C-30°C-60°C

Lining material:

Lining material

Main Performance

Applications

Teflon

1.The most steady material in plastics which is resistibal to boiling hydrochloric acid,vitriolandqua fortis as well as strong alkali and organic impregnates.     

 

 

Strong corrosive mediums such as strong acid and alkali

2.Not be perfect in abrasion resistance.

 

PFA

Having the same abrasion resistance with PTFE.

Applicable in state of load pressure

Having strong ability of load pressure resistance.

 

 

F46

1.Have the same abrasion resistance with PTFE.

  

1.The same as PTFE. 2.Applicable in mediums of low abrasion.

2.Resistable for low abrasion.

3.Having strong resistance to load pressure.

 

Neoprene

 1.Be of good elasticity,retractility and abrasion resistance.

Water,sewage and slurry,mineral 

2.Be resistant to low aicd,alkali and salt but not for oxidation mediums.

 

Polyurethane

1.Be of good abrasion resistibility.

 

Applicable in mineral serosity,slurry 

2.Not be perfect in acid/alkali resisitance.

3.Can't be used for water mixed with organic impregnants.

Electrode selection:

Electrode material

Applications

Stainless steel SUS316

Applicable in water,sewage and corrosive mediums.

Widely used in industries of petrol,chemistry,carbamide,etc

Stainless steel
covered with tungsten carbide

 

Applicable in mediums of no corrosive and low abrasion.

Hastelloy B(HB)

Having strong resistance to hydrochloric acid of any consistance which is below bioling  piont. Also resistable against vitriol,phosphate,hydrofluoricacid,organic acid etc which are oxidable  acid,alkali and non-oxidable salt.

Hastelloy C(HC)

Be resistant to oxidable acid such as nitric acid,mixed acid as well as oxidable salt such as Fe+++,Cu++and sea water

 

 

Titanium

Applicable in seawater,and kinds of chloride,hypochlorite salt, oxidable acid(including fuming nitric acid),organic acid,alkali etc.

Not resistant to a pure reducing acid(such as sulphuric acid,hydrochloric acid)corrosion.

But if acid contains antioxidant(such as Fe+++,Cu++)is greatly  reduce corrosion.

Da

In addition to hydrofluoric acid, fuming sulfuric acid, alkali remaining outside chemicals, including boiling hydrochloric acid

Platinum-iridium

Almost be applicable in all chemical mediums except for aqua fortis,ammonium salt.

Features

1.No move assembly, no abrasion ;
2.Measuring range rate: 1:100;
3.No flow enhance equipment;
4.Suits for various of electronic conductivity liquid;
5.No affect from temperature, viscosity, pressure and density;
6.Anti-corrosion of price electromagnetic flowmeter water ;
7.Measure both to and reverse flow;
8.Huge display, easy operate;
9.Long-term EEPROM to save data when lose power;
10.Support MODBUS/HART communication protocol;
11.Wide working volts range;
12.Self diagnose.

 

Application area                                                                                          

1. Drinking water supply, water supply, reservoir and pumping station etc.                                              2. Chemical acid, lye, conductive solution, cooling fluid, additives etc.

3. Drink water, beer, wine, alcohol, milk, yogurt, fruit juice, syrup, blood etc.

4. Refrigeration / air conditioning and refrigeration thermal measurement, or heat energy.

5. Sewage, industrial sewage discharge, sewage etc.

6.Control of metal industrial pump,cooling water and the flow of water.

7. The textile industry of water, pigments, chemicals, bleaching chemicals etc.


paste-pic-dp_uuid_i3jec


Order Sheet: ATWFD-

Name

Specification code

Explanation

Converter type

I

Integrated type

S

Split type

C

Insert type

Diameter code

xxx

For example:100 represents DN100

Electrode material

S

Stainless steel(316L)

P

Platinum Pt

H

Hastelloy B(HB)

Ta

Tantalum Ta

TI

Titanium Ti

HC

Hastelloy C(HC)

Lining material

RU

Chloroprene rubber

PR

Polyurethane rubber

F4

F4(PTFE) polytetrafluoroethylene

F46

F46(FEP)polyperfluoroethylene-propylene

Rated pressure(MPa)

16

1.6M Pa

25

2.5M Pa

Z

Customized

 Operating temperature

E

<80

H

<120

Grade of  protection

P1

IP65

P2

IP68

Case material

C

Carbon steel

SS

Stainless steel

Instrument flange

CS

Carbon steel

SS1

Stainless steel

Power supply source

PS1

220VAC(85V~265V)

PS2

24VDC(20-36VDC)

Out Put

O1

4-20mA, RS485 modbus protocol

O2

Pulse output

O3

4-20mA


CE & ISO9001 CERTIFICATES

 sanitary smart electromagnetic flowmeter with HART or RS485 Modbus Protocol

Company Introduction

factory0522.png


1. Q: Can you provide samples ? Are the samples free ?

A:We offer paid sample,around 4-5 days arrived your hand by DHL, FEDEX, UPS or EMS

 

2. Q: What kind of payment do you accept ? Can I pay RMB ?

A:Payment <=5000USD,100% in advance. Payment>=5000USD,50%T/T in advance,balance before shipment. And you can pay money In RMB. No problem.

 

3. Q : How to ship my order ? Is it safe?

A: For small package, we will send it by Express, such as DHL,FedEx,,UPS,TNT,EMS.That’s a Door to Door service.

 

4. Q: Do you have a guarantee of your product quality?

A: We have a guarantee of 18 month.

 

5. Q: Can I become an Agent / Dealer of your products?

A: Welcome! But please let me know your Country/Area first,We will have a check and then

talk about this.If you want any other kind of cooperation,do not hesitate to contact us.


Please contact us for price. Thank you.

Hot Tags: stainless steel electromagnetic beer flow meter rs485 4-20ma tri clamp, manufacturers, suppliers, factory
Related Products

Inquiry

  • Your Name:
  • *E-mail:
  • Phone:
  • Company:
  • Title:
  • *Content: