Digital and Inline Water Magnetic Flow Meter Measure Acid

digital and inline water magnetic flow meter measure acid Summery digital water flow meter converters are battery powered, capable of being used together with common electromagnetic flow meters, with the flow rate measurement accuracy up to 0.5 level and 0.2 level. That is to say, a new type of...

Send Inquiry

Product Details

digital and inline water magnetic flow meter measure acid


Summery

digital water flow meter converters are battery powered, capable of being used together with common electromagnetic flow meters, with the flow rate measurement accuracy up to 0.5 level and 0.2 level. That is to say, a new type of products — electromagnetic water meter series will be developed simply by connecting  convertor to a common electromagnetic flow meter.

The digital water flow meter converter is equipped with a lithium battery as its standard configuration, which can work over three consecutive years. If a high-capacity battery is equipped, the continuous working time will be much longer.


Performance indexes

■ Ambient temperature-20℃―60℃ 60℃-120℃

■ Ambient humidity≦95%

■ Level of protection for case: IP68

■ Measuring range of flow rate:0 --- 15m/s

■ Medium conductivity: clean water > 20 μs/cm

■ Range of nominal diameters measurableDN3―DN600

■ Accuracy grade of sensors: Grade 0.5, grade 0.2

■ Measurable parameters: instantaneous flow rate, instantaneous flow velocity

■ Recordable parameters: accumulative total of flow, record of 32 events

   Test alarm parameters: Fluid empty-tube test alarm

                        Exciting current test alarm

                        Battery capacity test alarm

■ Calibrated output signal: Flow and impulse per unit volume

■ Radio communication mode: SRD、GPRS、CDMA

 

4.1 The Round and vertical type, integral structure 

4.2 The round and horizontal type, integral structure

4.3 The square type, separate structure


5  Pictures of Convertors

 191558.png 191562.png

      Figure (A)               Figure (B)                Figure (C) 

Figure (A):The round and horizontal type, integral structure (with GPRS communication function)

Figure(B):The square type, separate structure

Figure (C):The Round and vertical type, integral structure(equipped with GPRS communication function)


Figure  Connection diagram for round convertors

Figure  Connection diagram for square convertors

POUT ――― Output            COM ――― Ground wire


Order sheet

Name

Specification code

Explanation

Instrument type

 

Intelligent electromagnetic flow meter

Diameter code

AT-xxx

For example:100 represents DN100

Electrode form

1

Standard stationary type

 

 

Electrode material

0

Stainless steel(316L)

1

Platinum Pt

2

Hastelloy B(HB)

3

Tantalum Ta

4

Titanium Ti

5

Hastelloy C(HC)

 

 

Lining material

3

Chloroprene rubber

4

Polyurethane rubber

5

F4(PTFE) polytetrafluoroethylene

6

F46(FEP)polyperfluoroethylene-propylene

 

 

Rated pressure(MPa)

4.0

DN10-80

1.6

DN100-150

1.0

DN200-1000

0.6

DN1100-2000

0.25

DN2200

 

Operating temperature

E

<80℃

H

<120℃

Grounding

 

Built-in grounding electrode

Grade of  protection

0

IP65

1

IP68

Converter type

0

Integral type

1

Split type

Case material

0

Carbon steel

1

Stainless steel

Instrument flange

0

Carbon steel

1

Stainless steel

Installing timing flange

0

Without

1

With

Power supply source

0

220VAC

1

24VDC

 

2

Battery

Instrument range

xxx

For example:(200)represents maximum
     fux corresponding to 20mA

Flow :200mm³/h


Related Products

Inquiry

  • Your Name:
  • *E-mail:
  • Phone:
  • Company:
  • Title:
  • *Content: